Hōʻea hou mai Kina Maya Lapaʻau 3 Part Automated Laboratory Blood Test Machine Auto Hematology Analyzer Price

Nā loina

● ʻO ke ʻano impedance

● Cyanide free colorimetric ala


Huahana Huahana

Huahana Huahana

Ke hilinaʻi nei mākou i ka noʻonoʻo hoʻolālā, ka hoʻololi mau ʻana i nā ʻāpana āpau, ka holomua ʻenehana a ʻoiaʻiʻo ma luna o kā mākou poʻe limahana e komo pololei i loko o kā mākou kūleʻa no Newly Arrival China Maya Medical 3 Part Automated Laboratory Blood Test Machine Auto Hematology Analyzer Price, Hiki iā mākou ke hana i nā huahana e like me i kāu mau koi a hiki iā mākou ke hoʻopaʻa iā ʻoe ke kauoha ʻoe.
Ke hilinaʻi nei mākou i ka noʻonoʻo hoʻolālā, ka hoʻololi mau ʻana i nā ʻāpana āpau, ka holomua ʻenehana a ʻoiaʻiʻo hoʻi ma luna o kā mākou limahana e komo pololei i loko o kā mākou kūleʻa nomea kālaiʻike hematology auto, Kina Hematology Analyzer, Loaʻa iā mākou kā mākou inoa inoa inoa a ke ulu wikiwiki nei kā mākou hui ma muli o nā mea kiʻekiʻe kiʻekiʻe, ke kumukūʻai hoʻokūkū a me ka lawelawe maikaʻi loa.Manaʻolana mākou e hoʻokumu i nā pilina ʻoihana me nā hoaaloha hou aʻe mai ka home a ma waho i ka wā e hiki mai ana.Ke kali nei mākou i kāu leka.
0244

Hōʻike ʻenehana

Nā ʻāpana

21 Nā ʻāpana hiki ke hōʻike ʻia:

WBC, Lym#, Mid#, Gran#, Lym%, Mid%, Gran%, RBC,

HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,

PDW, PCT, P-LCR, P-LCC

3 Histograms (WBC, RBC, PLT)

Ke ano hoao

ʻO ke koko holoʻokoʻa Venous, Capillary whole blood and Prediluted

Ka holo ana

60 ho'āʻo / hola

hana

ʻĀpana Laina Linearity Hapai CV
WBC 0-300×109 /L ≤0.5% ≤2.0%
RBC 0-8×1012 /L ≤0.5% ≤1.5%
HGB 0-250g/L ≤0.5% ≤1.5%
PLT 0-3000×109 /L ≤1.0% ≤4.0%

Laʻana Volume

≤10ul

Hoʻomanaʻo ʻIkepili

A hiki i 100,000 hopena (me nā histograms a me ka ʻike maʻi)

Hōʻike

10.4 iniha paʻi pale

Paipai

ʻO ka mīkini paʻi wela i kūkulu ʻia a i ʻole ka mīkini paʻi waho

Ikepili

● 4 USB, 1 LAN, 1 RS-232

● Kākoʻo i ka pilina LIS

● Kāleka RF no ka ʻōnaehana pani reagent (koho)

Nui / Kaumaha

L * W * H = 411*315*416(mm)

Kaumaha: 21kg

Kaiapuni Hana

● Mana: ac100-240V, 50/60Hz

● Mahana: 10-30 ℃

● Kaha: 20-85%

● Pumi ea: 70-106KPa

● Latitude Hana: ≤3500mKe hilinaʻi nei mākou ma luna o ka noʻonoʻo hoʻolālā, ka hoʻololi mau ʻana i nā ʻāpana āpau, ka holomua ʻenehana a ʻoiaʻiʻo ma luna o kā mākou poʻe limahana e komo pololei i loko o kā mākou kūleʻa no ka Newly Arrival China Maya Medical 3 Part Automated Laboratory Blood Test Machine Auto Hematology Analyzer Price, We hiki ke hoʻopilikino i nā huahana e like me kāu mau koi a hiki iā mākou ke hoʻopaʻa iā ʻoe ke kauoha ʻoe.
Hiki HouKina Hematology Analyzer, Auto Hematology Analyzer, Loaʻa iā mākou kā mākou inoa inoa inoa a ke ulu wikiwiki nei kā mākou hui ma muli o nā mea kiʻekiʻe, ke kumukūʻai hoʻokūkū a me ka lawelawe maikaʻi loa.Manaʻolana mākou e hoʻokumu i nā pilina ʻoihana me nā hoaaloha hou aʻe mai ka home a ma waho i ka wā e hiki mai ana.Ke kali nei mākou i kāu leka.